Máquina de ultrassom doppler portátil para abdômen para abdômen
$2100-3500 /Set/Sets
Tipo de pagamento: | T/T |
Incoterm: | FOB |
Quantidade de pedido mínimo: | 5 Set/Sets |
transporte: | Ocean,Land,Air,Express |
porta: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo de pagamento: | T/T |
Incoterm: | FOB |
Quantidade de pedido mínimo: | 5 Set/Sets |
transporte: | Ocean,Land,Air,Express |
porta: | Shenzhen,Ningbo,Shanghai |
Modelo: MDK-680
marca: Ultra -som unido
Color: white
Brand: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Lugar De Origem: China
Tipo De Poder: Eletricidade
Serviço De Garantia: 1 ano
Serviço Pós-venda: Peças de reposição grátis, Suporte técnico online
Material: metal, plástico
Classificação De Dispositivos Médicos: Classe II
Unidades de venda | : | Set/Sets |
Tipo de pacote | : | Carton |
Máquina de ultrassom Doppler portátil para abdômen (MDK-680)
É usado principalmente no fígado e rim, mas possui um valor diagnóstico auxiliar para distinguir lesões benignas e malignas na cavidade abdominal, câncer de vesícula biliar de polípitos grandes, inflamação crônica e grave e a diferença entre ducto biliar e arterial hepático.
O ultrassom de cores pode ser usado para determinar o tamanho do lúmen, a velocidade e a direção do fluxo interno e o estabelecimento da circulação colateral na cirrose hepática. Para esclerose nodular e câncer de fígado difuso, que são extremamente difíceis de distinguir entre preto e branco, pode facilitar o diagnóstico diferencial por exploração de alta frequência e exploração do espectro do fluxo sanguíneo.
Para o diagnóstico diferencial de espaço hepático benigno e maligno que ocupam lesões, cistos e vários tumores arteriovenosos têm melhor valor diagnóstico. O câncer de fígado primário e o câncer de fígado secundário também podem ser distinguidos pelo suprimento interno de sangue.
O ultrassom de cores é usado principalmente no rim para doenças vasculares renais. Como mencionado acima, quando as manifestações clínicas são hematúria septais e indolores, a causa não pode ser encontrada, existem fortes sinais de adaptação. Para estenose da artéria renal, uma das causas comuns da hipertensão secundária, o ultrassom de cores pode fazer um diagnóstico claro basicamente. Quando a vazão sanguínea na estenose foi superior a 150 cm/s, a precisão diagnóstica atingiu 98,6%e a sensibilidade foi de 100%. Por outro lado, é também o diagnóstico diferencial de carcinoma renal, carcinoma de transição da pelve renal e tumor benigno.
Nossos produtos:
Scanner de ultrassom preto e branco
Scanner de ultrassom de Doppler colorido
Scanner de ultrassom veterinário
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤4 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |
<20> |
Gynecological measurement and calculation function |
Measurement and calculation of uterus, left ovary, right ovary, left follicle, right follicle, etc |
<21> |
Obstetric measurement and calculation function |
G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD |
<22> |
Urology measurement and calculation function |
Measurement and calculation of left kidney, right kidney, bladder, residual urine volume, prostate, prostate specific antigen predicted value PPSA, prostate specific antigen density PSAD, etc |
<23> |
Product Size |
289×304×222mm |
<24> |
Carton Size |
395×300×410mm |
<25> |
N.W./ G.W. |
6kg/ 7kg |